    Specifications & Programming Instructions of CW5R 50NM Tubular Motor

    • Qualified persons must only carry out electrical connections.
    • The continuity of the earth connection provided for must be ensured.
    • It is recommended that the power supply of each CW5R 50NM Tubular Motor offers the possibility of being isolated. Even though each Tubular Motor comes with a in line connector plug.

    Transmitter Programming (Single or Multi Channel)

    1) Programming The First Transmitter

    If a multi-channel transmitter is being programmed, first select the channel required, by using the minus (-) or plus (+) button on the transmitter until you have located the required channel number to be programmed.

    • Connect the tubular motor to the power supply. The motor performs a brief up/down movement.
    • Within 10 seconds of this up/down movement –
    • Press and HOLD the UP & DOWN buttons on the transmitter together at the same time for more than 3 seconds until the motor performs a brief up/down movement followed by a second brief up/down/up/down movement, (approximately 3 seconds later)
    • The first transmitter is now programmed.
    2) Check the Direction of Rotation.

    If the direction of rotation is correct, (pressing up button makes the CW5R 50NM tubular motor raise the blind or shutter and pressing the down button lowers the blind or shutter) Proceed to step 4 – to change the way the CW5R 50NM tubular motor reacts to the remote control hand set.

    If the direction of rotation is NOT correct, proceed to step 3 to rectify this.

    3) Changing The Direction of Rotation
    • To change the direction of rotation, use the pre-programmed transmitter and follow the steps below.
    • Press the UP & DOWN buttons on the transmitter together at the same time. The Tubular Motor performs a brief up/down movement.
    • Then Press and HOLD the STOP button on the transmitter for approximately 3 seconds.  The  CW5R 50NM Tubular Motor performs a brief up/down movement.
    • Then Press the UP button on the transmitter. The  Tubular motor will perform a brief up/down/up/down movement.
    • The direction of rotation has now been changed.

    Check the direction of rotation is now correct. If it is not correct, go back to Step 3 and repeat this step again

    If this is now correct, proceed to step 4

    The following step will change the way the Tubular Motor reacts when the remote control up or down button is pressed.

    By default, the  CW5R 50NM  Tubular Motor will only move in a step by step way, when a single press of the button is given. The CW5R 50NM  Tubular Motor will not continue moving without holding the button down, until approximately 5 seconds of keeping the button pressed, only then will the Tubular Motor keep moving when the button is released.

    To change this reaction to the hand set to an immediate and continual movement with one single press, move to Step 4

    4) Changing Between Dot (Inching) And Continuous Movement Mode
    • Press the UP & DOWN buttons on the transmitter together at the same time until the CW5R 50NM  Tubular Motor performs a brief up/down movement.
    • Then Press and HOLD the STOP button on the transmitter for approximately 3 seconds until the  Tubular Motor performs a brief up/down movement.
    • Then press the STOP button on the transmitter. The Tubular Motorr will perform a brief up/down/up/down movement.
    • The motors mode of movement has now been changed.

    Check the mode of movement is now correct. If it is not correct, go back to Step 4 and repeat this step again

    If this is now correct, the programming is now complete.

    Additional programming options

    5) Adding a Second or Additional Transmitter

    If a second transmitter is required to be programmed, follow the steps below.

    If a multi-channel transmitter is being programmed, or has been programmed, first select the channel by using the minus (-) or plus (+) button on the transmitter to select the correct channel number.

    NEXT –

    • Press the UP & DOWN buttons on an EXISTING transmitter together at the same time until the CW5R 50NM  Tubular Motor performs a brief up/down movement.
    • Release, then Press and HOLD the STOP button on the EXISTING transmitter for approximately 3 seconds until the motor performs a brief up/down movement.
    • Then on the NEW transmitter you wish to use, Press the UP & DOWN buttons at the same time. The CW5R 50NM  Tubular Motor.
    • will perform a brief up/down/up/down movement and the new transmitter has now been memorized.
    6) Removing A Transmitter

    If a transmitter needs to be removed from the memory of the receiver, follow the steps below.

    • If a multi-channel transmitter is being removed, first select the channel to be removed by using the minus (-) or plus (+) button on the transmitter.
    • Then Press the UP & DOWN buttons on an EXISTING transmitter together at the same time until the CW5R 50NM  Tubular Motor performs a brief up/down movement.
    • Release, then Press and HOLD the STOP button on the transmitter for approximately 3 seconds until the Tubular Motor performs a brief up/down movement.
    • Then Press the DOWN button on the transmitter you wish to delete. The Tubular Motor will perform a brief up/down/up/down movement.
    • The ransmitter or selected channel on a transmitter has now been deleted.
    • Oz Roller Shutters only obligation shall be to repair or replace, with the least possible delay, defective equipment which does not conform to the warranty without any other indemnity relating to installation and re-installation or consequential damages.
    • Oz Roller Shutters shall not be liable for any injury, loss or damage, direct or consequential, arising out of the use of, or the inability to use, the equipment. Before using, the Buyer and/or the end User shall determine the suitability of the product for its intended use, and User assumes all risks and liability in connection therewith.
    • The articles that are replaced pursuant to the terms of this warranty shall be retained by Oz Roller Shutters.
    • All costs related to installation and re-installation of the Oz Roller Shutters equipment covered by this warranty are not the responsibility of Oz Roller Shutters.
    • The user is responsible for any freight costs relating to repair or replacement.
    • Oz Roller Shutters will not be responsible for any consequential damages during or following installation procedures.
    • If the buyer resells any Oz Roller Shutters products to another buyer or end-user, it shall include all of the terms and provisions of this warranty in such resale. Oz Roller Shutters responsibility to any such third party shall be no greater than Oz Roller Shutters responsibility under the warranty to the original Buyer.
    • If written specifications are not properly applied by the Buyer with regards to size and weight limitations.
    • If Oz Roller Shutters material is used with componentry and/or accessories that have not been previously approved in writing by Oz Roller Shutters.
    • If Oz Roller Shutters is requested by the Buyer to use any customized colors or to over coat materials then this will void warranty on Roller Shutter Coatings
    • If Oz Roller Shutters is requested by the Buyer to insert other profiles into a shutter (i.e. AE 401 into AR 401) then this will void the shutter due to the incompatibility of profiles
    • If the defect is a result of alteration, accident, misuse abuse or neglect.
    • Deterioration due to normal fair wear and tear.
    • Damage from weather and/or the environment including hail, wind, rain, lightening, flood, salt and similar.li>
    • Please Note: All Somfy® motors and mechanical accessories supplied by Oz Roller Shutters carry the Somfy® Five (5) Year Limited Warranty. All Somfy® controllers and electrical accessories supplied by Oz Roller Shutters carry the Somfy® Two (2) year Warranty.
    1
      1
      Your Cart
      E-Trans 1 Channel Remote
      1 X $65.00 = $65.00